C1.5

C1.5

Cat® C1.5 Diesel Marine Generator Set

Maximum Rating 12 ekW (12 kVA) 12 ekW (12 kVA)
Speed 1500 / 1800 rpm 1500 / 1800 rpm
Emissions U.S. EPA Tier 3 U.S. EPA Tier 3

Teknik Özellikler

Generator Set Specifications
Maximum Rating 12 ekW (12 kVA) 12 ekW (12 kVA)
Speed 1500 / 1800 rpm 1500 / 1800 rpm
Minimum Rating 10 ekW (10 kVA) 10 ekW (10 kVA)
Frequency 50 Hz or 60 Hz 50 Hz or 60 Hz
Engine Specifications
Emissions U.S. EPA Tier 3 U.S. EPA Tier 3
Configuration Inline 3, 4-Stroke Cycle diesel Inline 3, 4-Stroke Cycle diesel
Displacement 91 in³ 1.5 l
Aspiration Naturally Aspirated Naturally Aspirated
Governor Type Electrical Isochronous Electrical Isochronous
Bore 3.31 in 84 mm
Stroke 3.5 in 90 mm
Refill Capacity Lube Oil System w/oil filter change: 6 L (1.6 gal) Lube Oil System w/oil filter change: 6 L (1.6 gal)
Oil Change Interval 500 hrs 500 hrs
Rotation from Flywheel End Counterclockwise Counterclockwise
Cooling Hex or Single Circuit Keel Hex or Single Circuit Keel
Generator Set Dimensions
Length 40.8 in / 1,038 mm (open) 43.1 in / 711 mm (enclosed) 40.8 in / 1,038 mm (open) 43.1 in / 711 mm (enclosed)
Width 21.1 in / 535 mm (open) 24.0 in / 608 mm (enclosed) 21.1 in / 535 mm (open) 24.0 in / 608 mm (enclosed)
Height 27.1 in / 535 mm (open) 27.9 in / 711 mm (enclosed) 27.1 in / 535 mm (open) 27.9 in / 711 mm (enclosed)
Engine Dry Weight 703 lb / 319 kg 703 lb / 319 kg

Avantaj ve Özellikler

Key Features & Benefits

  • This compact unit provides required power on demand, operating very efficiently with optimum performance.
  • The 3 cylinder naturally aspirated engine operates with little vibration and low sound levels.
  • Available as an open set or with a sound enclosure, this package is ideal for power requirements in any application.
  • Low operating and maintenance costs with excellent fuel economy.
  • The single side servicing with extended service intervals makes maintenance easy.

Standart Donanımlar

  • Standard Equipment
    • Single element air cleaner
    • Water-cooled exhaust manifold
    • Single or Three phase brushless generator
    • 12 or 24 volt electric starting motor
    • 12 volt 55 amp alternator
    • Single sided service points
    • Anti-vibration mounts.
    • Electronic automatic safety shutdowns

İsteğe Bağlı Donanımlar

  • Optional Attachments
    • Sound attenuated enclosure (Factory Fit or Upgrade Kit)
    • Keel cooling kit
    • Basic, Deluxe and remote panel options
    • AC circuit breakers
    • Flexible fuel lines
    • Primary fuel filter/water separator
    • Siphon break
    • Exhaust system components
    • Insulated electrical system